Light Controller(Obstruction Light Controller)

Light Controller(Obstruction Light Controller) FR19

Obstruction Light Controller
Obstruction Light Controller

Features

AWL’s flash synchronously.

Fault alarm indicators on the panel and alarm signal output.

Alarm signal with dry contactpassive output.

Auto-Manual switchable, if don’t need photocell automatically switch function, it could be switched to manual control.

Photocell switch PJ003 for photocell function ( optional).

Optional fault switch function: when the main light fails, will switches to the standby light automatically.

Products description and application

General Specifications

Base

Product name

Obstruction Light Controller

Product model

FR19

Control Light Branch

8-way

single Load Power

4W-100W

Control Mode

Steady burning/Flashing

Flash Rate

20FPM, 30FPM, 40FPM and 60FPM

Alarm Output

Dry contact (Relay) output

Electric

Input Voltage

AC100-240V 

Output Voltage

DC48V

Frequency

50Hz/60Hz

Max Power Loaded

480W

SurgeLightning Protection

IEC61000-4-5 L- L 3kV
IEC61000-4-5 L-G 6kV

Electrostatic Discharge

IEC61000-4-2 Contact discharge8kV

Mechanical

Cabinet Material

Cold rolled plate with powder spray(RAL7038)

Weight

12.5kg(AC),9kg(DC) 

Storage Temperature

Ta-40 C~+70 C

Operating Temperature

Ta-40 C~+55 C

Ambient Humidity

10% ~ 95% (no coagulation)

IP Rate

IP65

Color


Grey(RAL7038)

Size

Obstruction Light Controller
Obstruction Light Controller

Product Application Pictures

Obstruction Light Controller

© Nanhua Electronics Co., Ltd.
沪ICP备10202509号-2